Linear motor is a kind of transmission device that converts electrical energy directly into mechanical energy for linear motion without any intermediate conversion mechanism. Its main advantage lies in the fast response, high acceleration and high linear motion speed, no friction, easy to control and adjust. Its working principle can be regarded as a rotary motor according to radial dissected and spread into a plane and become, the most commonly used type of linear motor is flat and U-slot type.

 

Flat Plate Linear Motors

 

U-type linear motors

 

Its main advantages are:

1. High stiffness, linear motors are directly connected to the load, therefore, between the motor and the load, there is no transmission gap, and in fact, there is no flexibility. When the linear motor drives the load movement, the iron core linear motor shows extremely high dynamic stiffness. 

 

2. High positioning accuracy, in the need for linear operation, linear motors can facilitate direct transmission, thus eliminating the intermediate links brought about by a variety of positioning errors, so the positioning accuracy is high, such as the use of microcomputer control, can also greatly improve the positioning accuracy of the entire system.

 

3. High-speed response As the system directly canceled some of the response time constant is large, such as screws and other mechanical transmission parts, so that the entire closed-loop control system dynamic response performance greatly improved, the response is exceptionally sensitive and fast. Quiet movement, low noise Due to the abolition of the mechanical friction of the drive screw and other components, and the guide can be used rolling guide or magnetic pad suspension guide (no mechanical contact), the movement of the noise will be greatly reduced.

 

4. The permanent magnets of linear motors are usually modular in design, and each module can be increased to any length according to the required number to realize infinite travel. However, in practice, it will be limited by cables or other factors.

 

5. High speed. Linear motors can facilitate highly accurate positional positioning control over a wide range of speeds, from high to low, by directly driving the load. The stator and actuator are both rigid parts, thus ensuring the quiet operation of the linear motor and the high rigidity of the core operating parts of the overall mechanism. The stroke of the linear motor can be made unlimited by splicing the stator, and multiple actuators can be configured on the same stator to allow multiple independent operations in the same axial direction.

 

Scope of Application:

1 Transportation:
High-speed railroad: linear motors are one of the key technologies for magnetic levitation trains (e.g. maglev trains).
Urban rail transportation: such as linear motor-driven subway system.

 

2 Industrial automation:
CNC machine tools: linear motors can directly drive the worktable to improve machining accuracy and efficiency.
Logistics system: such as electronic sorting system, automatic handling robot.

 

3 Precision instruments:
Measuring equipment: such as coordinate measuring machine, laser interferometer, etc.
Precision positioning platform: for semiconductor manufacturing equipment, optical instruments, etc.

 

4 Medical equipment:
Scanning components for high-speed CT, MRI and other imaging equipment.
Precision surgical robots.

 

5Aerospace:
Motion platforms for flight simulators.
Certain drive and control systems in spacecraft.

 

6 Printing Machinery:
Paper conveying and positioning systems for printing machines.

 

7 Electronics Manufacturing:
SMT mounter: for component placement on circuit boards.
LED production equipment: wafer placement, cutting and other processes.

 

8 Recreational facilities:
Roller coasters, simulators, etc. in amusement parks.

 

Magnetic properties of Sintered NdFeB magnets:

Grade

Residual magnetism 

Br

Coercivity

HcB

Endowed with coercivity

Hcj

Maximum magnetic energy product

(BH)max

Recommended maximum

working temperature

kGs T kOe kA/m kOe kA/m MGOe kJ/m3
L/D≥0.7
Max Min Max Min Min Min Min Min Max Min Max Min ℃
N30 11.3 10.8 1.13 1.08 ≥10 ≥796 ≥12 ≥955 31 28 247 223 ≤80
N33 11.8 11.3 1.18 1.13 ≥10.5 ≥836 ≥12 ≥955 34 31 271 247 ≤80
N35 12.2 11.8 1.22 1.18 ≥10.9 ≥868 ≥12 ≥955 36 33 287 263 ≤80
N38 12.6 12.2 1.26 1.22 ≥11.3 ≥899 ≥12 ≥955 39 36 311 287 ≤80
N40 12.9 12.6 1.29 1.26 ≥11.4 ≥907 ≥12 ≥955 41 38 327 302 ≤80
N42 13.3 12.9 1.33 1.29 ≥11.5 ≥915 ≥12 ≥955 43 40 342 318 ≤80
N45 13.7 13.3 1.37 1.33 ≥11.5 ≥915 ≥12 ≥955 46 43 366 342 ≤80
N48 14.1 13.7 1.41 1.37 ≥11 ≥876 ≥12 ≥955 49 45 390 358 ≤80
N50 14.5 14.0  1.45 1.40  ≥11 ≥876 ≥12 ≥955 51 47 406 374 ≤80
N52 14.8 14.3 1.48 1.43 ≥10.9 ≥868 ≥11 ≥876 53 49 422 390 ≤70
N55 15.2 14.6 1.52 1.46 ≥10.5 ≥836 ≥11 ≥876 55 51 438 406 ≤70
30M 11.3 10.8 1.13 1.08 ≥10 ≥796 ≥14 ≥1114 31 28 247 223 ≤100
33M 11.8 11.3 1.18 1.13 ≥10.5 ≥836 ≥14 ≥1114 34 31 271 247 ≤100
35M 12.2 11.8 1.22 1.18 ≥10.9 ≥868 ≥14 ≥1114 36 33 287 263 ≤100
38M 12.6 12.2 1.26 1.22 ≥11.3 ≥899 ≥14 ≥1114 39 36 311 287 ≤100
40M 12.9 12.6 1.29 1.26 ≥11.6 ≥923 ≥14 ≥1114 41 38 327 302 ≤100
42M 13.3 12.9 1.33 1.29 ≥12 ≥955 ≥14 ≥1114 43 40 342 318 ≤100
45M 13.7 13.3 1.37 1.33 ≥12.5 ≥995 ≥14 ≥1114 46 43 366 342 ≤100
48M 14.1 13.7 1.41 1.37 ≥12.9 ≥1027 ≥14 ≥1114 49 45 390 358 ≤100
50M 14.5 14.0  1.45 1.40  ≥13.,1 ≥1043 ≥14 ≥1114 51 47 406 374 ≤100
52M 14.7 14.2  1.47 1.42  ≥12.9 ≥1027 ≥14 ≥1114 53 49 422 390 ≤100
54M 15.2 14.7 1.52 1.47 ≥12.5 ≥995 ≥14 ≥1114 55 51 438 406 ≤100
30H 11.3 10.8 1.13 1.08 ≥10 ≥796 ≥17 ≥1353 31 28 247 223 ≤120
33H 11.8 11.3 1.18 1.13 ≥10.5 ≥836 ≥17 ≥1353 34 31 271 247 ≤120
35H 12.2 11.8 1.22 1.18 ≥10.9 ≥868 ≥17 ≥1353 36 33 287 263 ≤120
38H 12.6 12.2 1.26 1.22 ≥11.3 ≥899 ≥17 ≥1353 39 36 311 287 ≤120
40H 12.9 12.6 1.29 1.26 ≥11.6 ≥923 ≥17 ≥1353 41 38 327 302 ≤120

 

Grade

Residual magnetism

Br

Coercivity

HcB

Endowed with coercivity

Hcj

Maximum magnetic energy product

(BH)max

Recommended maximum

working temperature

kGs T kOe kA/m kOe kA/m MGOe kJ/m3
L/D≥0.7
Max Min Max Min Min Min Min Min Max Min Max Min ℃
42H 13.3 12.9 1.33 1.29 ≥12 ≥955 ≥17 ≥1353 43 40 342 318 ≤120
45H 13.7 13.3 1.37 1.33 ≥12.5 ≥995 ≥17 ≥1353 46 43 366 342 ≤120
48H 14.1 13.7 1.41 1.37 ≥12.9 ≥1027 ≥17 ≥1353 49 46 390 366 ≤120
50H 14.5 14.0  1.45 1.40  ≥13 ≥1034 ≥17 ≥1350 51 47 406 374 ≤120
52H 14.7 14.2  1.47 1.42  ≥13.5 ≥1074 ≥17 ≥1350 53 49 422 390 ≤120
30SH 11.4 10.8 1.14 1.08 ≥10.1 ≥804 ≥20 ≥1592 31 28 247 223 ≤150
33SH 11.8 11.4 1.18 1.14 ≥10.6 ≥844 ≥20 ≥1592 34 31 271 247 ≤150
35SH 12.2 11.8 1.22 1.18 ≥11.0 ≥876 ≥20 ≥1592 36 33 287 263 ≤150
38SH 12.6 12.2 1.26 1.22 ≥11.4 ≥907 ≥20 ≥1592 39 36 311 287 ≤150
40SH 12.9 12.6 1.29 1.26 ≥11.6 ≥939 ≥20 ≥1592 41 38 326 302 ≤150
42SH 13.3 12.9 1.33 1.29 ≥12.4 ≥987 ≥20 ≥1592 43 40 342 318 ≤150
45SH 13.7 13.2 1.37 1.32 ≥12.6 ≥1003 ≥20 ≥1592 46 42 366 334 ≤150
48SH 14.1 13.7 1.41 1.37 ≥12.9 ≥1027 ≥20 ≥1592 49 46 390 366 ≤150
50SH 14.5 14.0  1.45 1.40  ≥13 ≥1034 ≥20 ≥1592 51 47 406 374 ≤150
52SH 14.7 14.2  1.47 1.42  ≥13.5 ≥1074 ≥20 ≥1592 53 49 422 390 ≤150
28UH 10.8 10.4 1.08 1.04 ≥9.6 ≥764 ≥25 ≥1989 29 26 231 207 ≤180
30UH 11.4 10.8 1.14 1.08 ≥10.1 ≥804 ≥25 ≥1989 31 28 247 223 ≤180
33UH 11.8 11.4 1.18 1.14 ≥10.7 ≥852 ≥25 ≥1989 34 31 271 247 ≤180
35UH 12.2 11.8 1.22 1.18 ≥10.8 ≥860 ≥25 ≥1989 36 33 287 263 ≤180
38UH 12.6 12.2 1.26 1.22 ≥11.3 ≥899 ≥25 ≥1989 39 36 311 287 ≤180
40UH 12.9 12.5 1.29 1.25 ≥11.3 ≥899 ≥25 ≥1989 41 38 326 302 ≤180
42UH 13.3 12.8 1.33 1.28 ≥11.6 ≥923 ≥25 ≥1989 43 40 342 318 ≤180
45UH 13.7 13.2 1.37 1.32 ≥12.5 ≥995 ≥25 ≥1989 46 42 366 334 ≤180
28EH 10.8 10.4 1.08 1.04 ≥9.8 ≥780 ≥30 ≥2388 29 26 231 207 ≤200
30EH 11.4 10.8 1.14 1.08 ≥10.1 ≥804 ≥30 ≥2388 31 28 247 223 ≤200
33EH 11.8 11.4 1.18 1.14 ≥10.3 ≥820 ≥30 ≥2388 34 31 271 247 ≤200
35EH 12.2 11.8 1.22 1.18 ≥10.5 ≥836 ≥30 ≥2388 36 33 287 263 ≤200
38EH 12.6 12.2 1.26 1.22 ≥11.3 ≥899 ≥30 ≥2388 39 35 311 278 ≤200

 

Grade

Residual magnetism

Br

Coercivity

HcB

Endowed with coercivity

Hcj

Maximum magnetic energy product

(BH)max

Recommended maximum

working temperature

kGs T kOe kA/m kOe kA/m MGOe kJ/m3
L/D≥0.7
Max Min Max Min Min Min Min Min Max Min Max Min ℃
40EH 12.9 12.5 1.29 1.25 ≥11.3 ≥899 ≥30 ≥2388 41 38 326 302 ≤200
42EH 13.3 12.8 1.33 1.28 ≥11.6 ≥923 ≥30 ≥2388 43 40 342 318 ≤200
45EH 13.7 13.2 1.37 1.32 ≥12.5 ≥995 ≥30 ≥2388 46 42 366 334 ≤200
28AH 10.9 10.4 1.09 1.04 ≥9.8 ≥780 ≥35 ≥2785 29 26 231 207 ≤230
30AH 11.3 10.8 1.13 1.08 ≥10.1 ≥804 ≥35 ≥2785 31 28 247 223 ≤230
33AH 11.8 11.3 1.18 1.13 ≥10.3 ≥820 ≥35 ≥2785 34 31 271 247 ≤230
35AH 12.2 11.8 1.22 1.18 ≥10.5 ≥860 ≥35 ≥2785 36 33 287 263 ≤230
38AH 12.6 12.2 1.26 1.22 ≥11.3 ≥899 ≥35 ≥2785 39 35 311 278 ≤230

Note: The above magnetic performance parameters are tested at 20℃~23℃ room temperature.

 

Grade

Residual magnetism

Br

Coercivity

HcB

Endowed with coercivity

Hcj

Maximum magnetic energy product

(BH)max

kGs T kOe kA/m kOe kA/m MGOe kJ/m3
Max Min Max Min Min Min Min Min Max Min Max Min
G50SH 14.4  13.9  1.44  1.39  13.0  1035 20  1592 50 47 398 374
G50SHT 14.4  13.9  1.44  1.39  13.0  1035 22  1751 50 47 398 374
G52SH 14.6  14.2  1.46  1.42  13.2  1050 20  1592 52 49 414 390
G52SHT 14.6  14.2  1.46  1.42  13.2  1050 22  1751 52 49 414 390
G45UH 13.7  13.2  1.37  1.32  12.4  987 25  2149 46 42 366 334
G45UHT 13.7  13.2  1.37  1.32  12.4  987 27  2149 46 42 366 334
G48UH 14.0  13.6  1.40  1.36  12.7  1011 25  1990 48 45 382 358
G48UHT 14.0  13.6  1.40  1.36  12.7  1011 27  2149 48 45 382 358
G50UH 14.4  13.9  1.44  1.39  13.0  1035 25  1990 50 47 398 374
G52UH 14.5  14.2  1.45  1.42  13.7  1090 26  1989 52 49 414 390
G42EHT 13.3 12.8 1.33 1.28 12.0  955 32  2547 43 40 342 318
G45EH 13.7  13.2  1.37  1.32  12.4  987 30  2388 46 42 366 334
G45EHT 13.7  13.2  1.37  1.32  12.4  987 32 2547 46 42 366 334
G38AHT 12.6  12.1  1.26  1.21  11.8  939 37 2945 39 35 310 278
G40AH 12.9 12.5 1.29 1.25 12.0  955 35 2786 41 38 326 302
G40AHT 12.9 12.5 1.29 1.25 12.0  955 37 2945 41 38 326 302
G42AH 13.3 12.8 1.33 1.28 12.0  955 35 2786 43 40 342 318

Note: The above magnetic performance parameters are tested at 20℃~23℃ room temperature.

 

Featured Products

Messages

If you are interested in our products, please leave us a message and we will contact you promptly.

%{tishi_zhanwei}%

Messages

If you are interested in our products, please leave us a message and we will contact you as soon as possible!

%{tishi_zhanwei}%