ALVIN MAGNETS

PRODUCTS

undefined
undefined
+
  • undefined
  • undefined

Halbach Components


The Bovine Gastric Magnet is a veterinary medical device used to treat and prevent diseases of bovine hardware.

keyword:

Motor Rotor
Laminated Magnet
Magnetic couplings
Linear Motor
Halbach Components

Detail


The Halbach array is a special arrangement of magnets, invented by American physicist Klaus Halbach in 1980. The array is characterized by a magnetic field that is very concentrated on one side of the array and almost zero on the other.Halbach arrays are made by skillfully arranging permanent magnets so that the magnetic lines of force are enhanced on one side of the array and cancel each other out on the opposite side.

 

Characteristics of Halbach array:

1. Asymmetry of the magnetic field: this is the most significant feature of the Halbach array. The magnetic field is strong on one side of the array and almost disappears across 180 degrees.
2. Localized enhancement of the magnetic field: It is possible to generate a more concentrated magnetic field on one side of the array than conventional magnets.
3. Adjustability of the magnetic field: By changing the arrangement and size of the magnets, the magnetic field distribution can be adjusted.

 

Application areas:

1. Motors and generators: Halbach arrays can be used to create more efficient and smaller motors and generators.
2. Magnetic levitation devices: The use of a strong magnetic field on one side of the array can be used to achieve stable magnetic levitation of objects.
3. Medical devices: In magnetic resonance imaging (MRI), Halbach arrays can be used to generate a more uniform magnetic field.
4. Sensors: Sensors used to accurately measure parameters such as angle and position.
5. Linear actuators: In linear motion applications where precise control is required.

 

Principle of operation:

Halbach arrays work by arranging magnets in a regular pattern (usually alternating polarity) so that the magnetic fields of each magnet are superimposed on each other in space. On one side of the array, these fields reinforce each other, while on the other side they cancel each other out, resulting in a significantly stronger magnetic field on one side of the array and a significantly weaker field on the other side, thus producing a stronger magnetic field with fewer magnets.

 

Below is a comparison between the effect of a normal magnet arrangement and the effect of a Halbach array arrangement.

 

This is a practical application of Helbeh

 

(2-stage Heilbech motor stator consisting of 16 magnets)

 

The following is the waveform and magnetic field distribution of the stator

 

The magnetic field is sinusoidally distributed, and the greater the number of magnets in each pole, the higher the degree of sinusoidal distribution.

 

Advantages:

* Reduce the harmonic of motor.
* Enlarge air gap of motor 
* Increased utilization of magnetic field

 

Magnetic properties of Sintered NdFeB magnets:

Grade

Residual magnetism 

Br

Coercivity

HcB

Endowed with coercivity

Hcj

Maximum magnetic energy product

(BH)max

Recommended maximum

working temperature

kGs T kOe kA/m kOe kA/m MGOe kJ/m3
L/D≥0.7
Max Min Max Min Min Min Min Min Max Min Max Min ℃
N30 11.3 10.8 1.13 1.08 ≥10 ≥796 ≥12 ≥955 31 28 247 223 ≤80
N33 11.8 11.3 1.18 1.13 ≥10.5 ≥836 ≥12 ≥955 34 31 271 247 ≤80
N35 12.2 11.8 1.22 1.18 ≥10.9 ≥868 ≥12 ≥955 36 33 287 263 ≤80
N38 12.6 12.2 1.26 1.22 ≥11.3 ≥899 ≥12 ≥955 39 36 311 287 ≤80
N40 12.9 12.6 1.29 1.26 ≥11.4 ≥907 ≥12 ≥955 41 38 327 302 ≤80
N42 13.3 12.9 1.33 1.29 ≥11.5 ≥915 ≥12 ≥955 43 40 342 318 ≤80
N45 13.7 13.3 1.37 1.33 ≥11.5 ≥915 ≥12 ≥955 46 43 366 342 ≤80
N48 14.1 13.7 1.41 1.37 ≥11 ≥876 ≥12 ≥955 49 45 390 358 ≤80
N50 14.5 14.0  1.45 1.40  ≥11 ≥876 ≥12 ≥955 51 47 406 374 ≤80
N52 14.8 14.3 1.48 1.43 ≥10.9 ≥868 ≥11 ≥876 53 49 422 390 ≤70
N55 15.2 14.6 1.52 1.46 ≥10.5 ≥836 ≥11 ≥876 55 51 438 406 ≤70
30M 11.3 10.8 1.13 1.08 ≥10 ≥796 ≥14 ≥1114 31 28 247 223 ≤100
33M 11.8 11.3 1.18 1.13 ≥10.5 ≥836 ≥14 ≥1114 34 31 271 247 ≤100
35M 12.2 11.8 1.22 1.18 ≥10.9 ≥868 ≥14 ≥1114 36 33 287 263 ≤100
38M 12.6 12.2 1.26 1.22 ≥11.3 ≥899 ≥14 ≥1114 39 36 311 287 ≤100
40M 12.9 12.6 1.29 1.26 ≥11.6 ≥923 ≥14 ≥1114 41 38 327 302 ≤100
42M 13.3 12.9 1.33 1.29 ≥12 ≥955 ≥14 ≥1114 43 40 342 318 ≤100
45M 13.7 13.3 1.37 1.33 ≥12.5 ≥995 ≥14 ≥1114 46 43 366 342 ≤100
48M 14.1 13.7 1.41 1.37 ≥12.9 ≥1027 ≥14 ≥1114 49 45 390 358 ≤100
50M 14.5 14.0  1.45 1.40  ≥13.,1 ≥1043 ≥14 ≥1114 51 47 406 374 ≤100
52M 14.7 14.2  1.47 1.42  ≥12.9 ≥1027 ≥14 ≥1114 53 49 422 390 ≤100
54M 15.2 14.7 1.52 1.47 ≥12.5 ≥995 ≥14 ≥1114 55 51 438 406 ≤100
30H 11.3 10.8 1.13 1.08 ≥10 ≥796 ≥17 ≥1353 31 28 247 223 ≤120
33H 11.8 11.3 1.18 1.13 ≥10.5 ≥836 ≥17 ≥1353 34 31 271 247 ≤120
35H 12.2 11.8 1.22 1.18 ≥10.9 ≥868 ≥17 ≥1353 36 33 287 263 ≤120
38H 12.6 12.2 1.26 1.22 ≥11.3 ≥899 ≥17 ≥1353 39 36 311 287 ≤120
40H 12.9 12.6 1.29 1.26 ≥11.6 ≥923 ≥17 ≥1353 41 38 327 302 ≤120

 

Grade

Residual magnetism

Br

Coercivity

HcB

Endowed with coercivity

Hcj

Maximum magnetic energy product

(BH)max

Recommended maximum

working temperature

kGs T kOe kA/m kOe kA/m MGOe kJ/m3
L/D≥0.7
Max Min Max Min Min Min Min Min Max Min Max Min ℃
42H 13.3 12.9 1.33 1.29 ≥12 ≥955 ≥17 ≥1353 43 40 342 318 ≤120
45H 13.7 13.3 1.37 1.33 ≥12.5 ≥995 ≥17 ≥1353 46 43 366 342 ≤120
48H 14.1 13.7 1.41 1.37 ≥12.9 ≥1027 ≥17 ≥1353 49 46 390 366 ≤120
50H 14.5 14.0  1.45 1.40  ≥13 ≥1034 ≥17 ≥1350 51 47 406 374 ≤120
52H 14.7 14.2  1.47 1.42  ≥13.5 ≥1074 ≥17 ≥1350 53 49 422 390 ≤120
30SH 11.4 10.8 1.14 1.08 ≥10.1 ≥804 ≥20 ≥1592 31 28 247 223 ≤150
33SH 11.8 11.4 1.18 1.14 ≥10.6 ≥844 ≥20 ≥1592 34 31 271 247 ≤150
35SH 12.2 11.8 1.22 1.18 ≥11.0 ≥876 ≥20 ≥1592 36 33 287 263 ≤150
38SH 12.6 12.2 1.26 1.22 ≥11.4 ≥907 ≥20 ≥1592 39 36 311 287 ≤150
40SH 12.9 12.6 1.29 1.26 ≥11.6 ≥939 ≥20 ≥1592 41 38 326 302 ≤150
42SH 13.3 12.9 1.33 1.29 ≥12.4 ≥987 ≥20 ≥1592 43 40 342 318 ≤150
45SH 13.7 13.2 1.37 1.32 ≥12.6 ≥1003 ≥20 ≥1592 46 42 366 334 ≤150
48SH 14.1 13.7 1.41 1.37 ≥12.9 ≥1027 ≥20 ≥1592 49 46 390 366 ≤150
50SH 14.5 14.0  1.45 1.40  ≥13 ≥1034 ≥20 ≥1592 51 47 406 374 ≤150
52SH 14.7 14.2  1.47 1.42  ≥13.5 ≥1074 ≥20 ≥1592 53 49 422 390 ≤150
28UH 10.8 10.4 1.08 1.04 ≥9.6 ≥764 ≥25 ≥1989 29 26 231 207 ≤180
30UH 11.4 10.8 1.14 1.08 ≥10.1 ≥804 ≥25 ≥1989 31 28 247 223 ≤180
33UH 11.8 11.4 1.18 1.14 ≥10.7 ≥852 ≥25 ≥1989 34 31 271 247 ≤180
35UH 12.2 11.8 1.22 1.18 ≥10.8 ≥860 ≥25 ≥1989 36 33 287 263 ≤180
38UH 12.6 12.2 1.26 1.22 ≥11.3 ≥899 ≥25 ≥1989 39 36 311 287 ≤180
40UH 12.9 12.5 1.29 1.25 ≥11.3 ≥899 ≥25 ≥1989 41 38 326 302 ≤180
42UH 13.3 12.8 1.33 1.28 ≥11.6 ≥923 ≥25 ≥1989 43 40 342 318 ≤180
45UH 13.7 13.2 1.37 1.32 ≥12.5 ≥995 ≥25 ≥1989 46 42 366 334 ≤180
28EH 10.8 10.4 1.08 1.04 ≥9.8 ≥780 ≥30 ≥2388 29 26 231 207 ≤200
30EH 11.4 10.8 1.14 1.08 ≥10.1 ≥804 ≥30 ≥2388 31 28 247 223 ≤200
33EH 11.8 11.4 1.18 1.14 ≥10.3 ≥820 ≥30 ≥2388 34 31 271 247 ≤200
35EH 12.2 11.8 1.22 1.18 ≥10.5 ≥836 ≥30 ≥2388 36 33 287 263 ≤200
38EH 12.6 12.2 1.26 1.22 ≥11.3 ≥899 ≥30 ≥2388 39 35 311 278 ≤200

 

Grade

Residual magnetism

Br

Coercivity

HcB

Endowed with coercivity

Hcj

Maximum magnetic energy product

(BH)max

Recommended maximum

working temperature

kGs T kOe kA/m kOe kA/m MGOe kJ/m3
L/D≥0.7
Max Min Max Min Min Min Min Min Max Min Max Min ℃
40EH 12.9 12.5 1.29 1.25 ≥11.3 ≥899 ≥30 ≥2388 41 38 326 302 ≤200
42EH 13.3 12.8 1.33 1.28 ≥11.6 ≥923 ≥30 ≥2388 43 40 342 318 ≤200
45EH 13.7 13.2 1.37 1.32 ≥12.5 ≥995 ≥30 ≥2388 46 42 366 334 ≤200
28AH 10.9 10.4 1.09 1.04 ≥9.8 ≥780 ≥35 ≥2785 29 26 231 207 ≤230
30AH 11.3 10.8 1.13 1.08 ≥10.1 ≥804 ≥35 ≥2785 31 28 247 223 ≤230
33AH 11.8 11.3 1.18 1.13 ≥10.3 ≥820 ≥35 ≥2785 34 31 271 247 ≤230
35AH 12.2 11.8 1.22 1.18 ≥10.5 ≥860 ≥35 ≥2785 36 33 287 263 ≤230
38AH 12.6 12.2 1.26 1.22 ≥11.3 ≥899 ≥35 ≥2785 39 35 311 278 ≤230

Note: The above magnetic performance parameters are tested at 20℃~23℃ room temperature.

 

Grade

Residual magnetism

Br

Coercivity

HcB

Endowed with coercivity

Hcj

Maximum magnetic energy product

(BH)max

kGs T kOe kA/m kOe kA/m MGOe kJ/m3
Max Min Max Min Min Min Min Min Max Min Max Min
G50SH 14.4  13.9  1.44  1.39  13.0  1035 20  1592 50 47 398 374
G50SHT 14.4  13.9  1.44  1.39  13.0  1035 22  1751 50 47 398 374
G52SH 14.6  14.2  1.46  1.42  13.2  1050 20  1592 52 49 414 390
G52SHT 14.6  14.2  1.46  1.42  13.2  1050 22  1751 52 49 414 390
G45UH 13.7  13.2  1.37  1.32  12.4  987 25  2149 46 42 366 334
G45UHT 13.7  13.2  1.37  1.32  12.4  987 27  2149 46 42 366 334
G48UH 14.0  13.6  1.40  1.36  12.7  1011 25  1990 48 45 382 358
G48UHT 14.0  13.6  1.40  1.36  12.7  1011 27  2149 48 45 382 358
G50UH 14.4  13.9  1.44  1.39  13.0  1035 25  1990 50 47 398 374
G52UH 14.5  14.2  1.45  1.42  13.7  1090 26  1989 52 49 414 390
G42EHT 13.3 12.8 1.33 1.28 12.0  955 32  2547 43 40 342 318
G45EH 13.7  13.2  1.37  1.32  12.4  987 30  2388 46 42 366 334
G45EHT 13.7  13.2  1.37  1.32  12.4  987 32 2547 46 42 366 334
G38AHT 12.6  12.1  1.26  1.21  11.8  939 37 2945 39 35 310 278
G40AH 12.9 12.5 1.29 1.25 12.0  955 35 2786 41 38 326 302
G40AHT 12.9 12.5 1.29 1.25 12.0  955 37 2945 41 38 326 302
G42AH 13.3 12.8 1.33 1.28 12.0  955 35 2786 43 40 342 318

Note: The above magnetic performance parameters are tested at 20℃~23℃ room temperature.

 

Featured Products

Messages

If you are interested in our products, please leave us a message and we will contact you promptly.

%{tishi_zhanwei}%

Messages

If you are interested in our products, please leave us a message and we will contact you as soon as possible!

%{tishi_zhanwei}%